Emulex drivers for vmware esxi user guide. The PMAC PC104 CMM Interface is the communication link between the Geomet family of products and the motion controller for the DCC style CMM.
Installing the PMAC PC104 for the first time
When you are required to load the PMAC motion control drivers for the first time, for example on a new computer, there is a built in Add Hardware Wizard in Windows to assist the installation. The Wizard will appear when you attach the USB cable between the PMAC motion controller and the computer, see figure 1.
Nov 18, 2019 Val Kilmer made another public appearance, this time attending an art show at his own art studio on Friday. The 59-year-old Top Gun 2 star attended the GLAM Art Exhibition at his HelMel studios in Los Angeles, posing with artist Tamie Adaya and sporting a longer hairstyle than fans have seen recently. 1 day ago The Coordinate Measuring Machine Systems Market report is a compilation of first-hand information, qualitative and quantitative assessment by industry analysts, inputs from industry experts and industry participants across the value chain. The report provides in-depth analysis of parent market trends, macro-economic indicators and governing factors along with market attractiveness as per. ↳ Helmel ↳ Wenzel / Pantec ↳ Renishaw ↳ Deva ↳ I / DME ↳ Manual Interface - Insight / Caliper Design / TOPMES; Portable CMM's ↳ zCat DCC ↳ FARO ↳ Romer / CimCore ↳ Nikon MCA I / II / X ↳ Optical CMM / Krypton ↳ MicroScribe ↳ Baces3D / Kreon ↳ Nikon iGPS / iSpace ↳ RPS Metrology Smart Arm.
figure 1, New Hardware Found | figure 2, Select Search Options |
You will need the Geomet Installer CD to perform this installation. On the Found New Hardware choose 'Install from a list or specific location (Advanced)' and select <Next>. The next page in the Wizard prompts for search locations, see figure 2. Place a check next to both options and use the <Browse> button to locate the folder DriversPC 104 Driverspmcusb20 on the Geomet CD. Press the <Next> button.
After the Wizard completes the search, a list will be displayed from which you can choose which driver to install. Locate the driver in the folder ..pmacusb20pmacusb.inf as shown in figure 3. Select <Next>. The Wizard will read the driver installation script and display a confirmation page, see figure 4. Press <Continue Anyway>.
figure 5, install Progress | figure 6, Installation Complete |
The Wizard will display the installation progress page, see figure 5. When the driver installation is complete, the Wizard will display a confirmation page select <Finish>, see figure 6. To confirm the installation, use the Windows Device Manager. Download feig electronic port devices driver.
Under normal conditions, Geomet installs the proper files required for the PMAC PC104 card and establishes communications. Should a condition arise where the Windows system does not recognize the USB connection to the PC104 a quick check using the Device Manager can be used.
To launch the Device Manager, locate your Windows Control Panel (on XP, Start Menu→Control Panel) and locate 'System'. The System Properties tabbed dialog appears which you would choose the 'Hardware' tab. Next select the <Device Manager> button and the Device Manager tool appears, see figure 7.
figure 7, Windows Device Manager |
Expand the tree to show 'Universal Serial Bus controllers'. There should be an entry for 'Delta Tau PC104 USB Device' as shown highlighted in figure 7. If an error with the installation has been noted, there will be a '?' next to the name. In some cases, the device name will not be displayed or has a generic name. In this case the name 'Delta Tau..' will not appear. If this condition exists it is possible the installation of the files has failed or a conflict exists with another device. Contact Helmel support for assistance.
The CMM Interface controller is designed to work with many communication formats, ISA Bus, USB, or RS-232 just to name three. When the communications have not been previously established, the user can set the communication mode by choosing [System→Interface Configuration] from the main pull-down menus in Geomet, see figure 8.
figure 8, PMAC Communications |
Depress the button <In PC Bus> in the 'Device Location' group and set the check on USB Mode. To test the communications, press the <Ok> button and the connection through the USB port will be tested. If successful a message will display noting a connection has been made.
If communications could not be established please reference to the following chart.
Tctrl13.ocx PMAC PC104 Folder Installation Version 6.3.16.4 | |
Loose Cable | Check that the USB cable is seated correctly at the computer and on the PMAC motion controller. |
Power Connections | Ensure you have power supplied to the motion controller. The LED 'D2 PWR' should be green. |
Required Software Files | PMAC PC104 requires the installation of software support files. These are: pmac.dll pmac.vxd They are normally installed when the Geomet installation takes place. Depending on the operating system they will be installed, see Table 1. |
Device Manager | Check the system Device Manager to ensure the operating system recognizes the USB installation, see figure 2. |
NOTE: In all cases, cycle the power to Geomet and the electronics cabinet. Windows offers many tools to perform a diagnosis at startup which may detect, and correct, problems within devices attached to the USB. |
The CMM Interface has several options that must be set for proper operation. To activate the setuptools you must first have the Interface Data Strip shown, see figure 9. If this data strip is not shown, refer to Toolbar Status.
Helmel Driver Ed
figure 9, Interface Data Strip | figure 10, Selecting Joystick defaults |
To activate the Joystick Default tool, position the mouse pointer over the data strip and right-click to activate the sub-menu. see figure 9. Select [Joystick Defaults], see figure 10.
Depending on your Joystick series, see below, you will have control over the directions. When a series 1 or 2 is installed on your CMM, the setup tool will resemble figure 11. When the motion controller, PMAC, has control over the joystick, the parameters and behaviors are disabled and your setup tool will look like figure 12.
figure 11, Joystick Defaults | figure 12, PMAC Controlled Joysticks |
To establish the direction of motion relative to the deflection of the joysticks, there are check boxes to reverse the direction of motion if required. For example, if the joysticks are deflected in the +Y direction and the CMM moves in the -Y direction, place a check next to the 'Reverse Y Direction' label. As shown in figure 11, both the Y and Z direction have been reversed.
Helmel Driver License
Joystick Deflect Setting
These values are used primarily for testing and are not utilized by Geomet.
The joystick control has gone through a series of engineering changes. It is important to understand which series your joystick belongs too. Identifying which series you are using requires that you shut down Geomet and the electronic cabinet. Remove the cable from the joystick housing and matching the connector to the styles shown in figures 12, 13 and 14.
Geomet Joystick Series Identification Table | ||
Click here for a larger Image | Click here for a larger Image | Click here for a larger Image |
figure 13 | figure 14 | figure 15 |
Series 1 | Series 1, as shown in figure 13 has a connector containing 15 pins in a double row. The joystick connects to the game port of the Geomet computer system. | |
Series 2 | Series 2, as shown in figure 14 has a connector containing 9 pins in a double row. The joystick connects through a USB connection to the electronic cabinet to an Interconnect card. From the Interconnect card, there is a connection to the USB port on the Geomet computer system. The Geomet system controlled the motion of the CMM by interpreting the joystick deflections. | |
Series 3 | Series 3, as shown in figure 15 has a connector containing 15 pins in a triple row. The joystick connects through a USB connection to the electronic cabinet to a Interconnect card. From the Interconnect card, there is a connection to the USB port on the Geomet computer system. The Geomet system controlled only the button presses and the PMAC controlled the motion of the CMM by interpreting the joystick deflections. |
Related Procedures:
Digital equipment laptops amazon. The ProCounter III CMM Interface is designed for use on manual CMMs equiped with Renishaw scales. Connects to the host CMM software system through a USB 2.0 link and plug compatible to the CMM, specifically the Helmel CheckMaster or Microstar series. Other CMM manufacturers may require an adapter for connection.
The ProCounter III provides support for Renishaw touch probe systems and does not require a probe interface.
Application | Manual CMM to Host Software Interface (Helmel CheckMaster or Microstar) |
Power supply | 100 V - 264 VAC, 50 Hz - 60Hz |
Dimensions | Height: 56 mm (2.2 in) Width: 280 mm (11 in) Depth: 183 mm (7.2 in) |
Input | 12 VDC, 2.1mm x 5.5mm center positive standard |
USB | USB Type B Male |
X,Y and Z Scales | 15 Pin Female D-Sub |
Touch Probe | 9 Pin Female D-Sub |
Compatibility | Direct drivers for Geomet (requires separate driver installation-included) Windows 7 and 8 |
In the box | ProCounter III CMM Interface 120 VAC to 12 VDC Power Adapter 6' USB Cable Driver Installation CD for Windows 7 and 8 |
NOTE: The ProCounter III CMM Interface is plug compatible to Helmel CMMs. A cable adapter kit is required for use with other brands of CMMs.